  • undefined

UX-CDL series products

UX-CDL series product features: 1, fully enclosed equipment, long service life 2. Parabolic reflector, the highest efficiency 3. Can be installed horizontally or at a 45 degree angle 4. Self-diagnosis Ignition Control Unit 5. Jet generator, more uniform heat distribution and better combustion effect

Key words:

UX-CDL series product features

1, fully enclosed equipment, long service life

2. Parabolic reflector, the highest efficiency

3. Can be installed horizontally or at a 45 degree angle

4. Self-diagnosis Ignition Control Unit

5. Jet generator, more uniform heat distribution and better combustion effect

(I) micro positive pressure (The micro positive pressure), linear (Line), monomer (Single) series (such equipment is suitable for exhaust)

Technical Parameters of UX-CDL Series Products

Equipment Model

UX-CDL11

UX-CDL23

UX-CDL35

UX-CDL40

UX-CDL45

UX-CDL50

Heating capacity (kW)

11

23

35

40

45

50

Heating capacity (kcal/h)

9460

19780

30100

34400

38700

43000

Gas Supply Requirements

Air inlet interface: 1/2 "thread;

Natural gas pressure range at the gas inlet of natural gas equipment: 1500Pa ~ 3500Pa, gas pressure at the equipment nozzle: 875Pa;

The pressure range of liquefied gas at the air inlet of liquefied gas equipment is 3000Pa ~ 5000Pa, and the gas pressure at the equipment nozzle is 2625Pa.

Natural gas consumption (m³)

Gas calorific value: 9000kcal/m³

1.05

2.19

3.33

3.81

4.29

4.76

Gas consumption of liquefied petroleum gas (m³)

Calorific value of gas: 25000kcal/m³

0.38

0.79

1.20

1.38

1.55

1.72

Power Supply Requirements

220V,50Hz;

Single-unit equipment, power distribution of each set of equipment: 65W (including burner: 5W, small fan: 60W);

Total length (m)

3

6 (standard)/9

9 (standard)/12

12 (standard)/15

12/15 (standard)

15 (standard)/18

Total width (mm)

406

406

406

406

406

406

Total height (mm)

381

381

381

381

381

381

Fresh Air Duct and Exhaust Duct

Interface size (mm)

102

Recommended minimum installation height (m)

3.0

3.3

4.2

4.7

4.9

5.1

Weight (kg)

28

44/59

59/75

75/90

75/90

90/106

With spoiler

×

×

×

Distance from combustibles (mm)

Upper end of reflector

50

50

100

100

100

100

Both ends of the reflector

460

660

840

915

970

1020

Lower end of radiant tube

1140

1575

1800

1880

1930

1980

For example, UX-CDL50 product code explanation:

UX Canadian Factory Product Series Number

CD-Xindier brand radiant heating products.

L-linear combination form

50 -- Heating capacity 50kW

(II) Micro-negative pressure (Negative pressure), linear (Line), single (Single)/composite (Complex) series (such equipment is suitable for exhaust gas discharge)

 

 

UX-CDL()V series product technical parameter table:

Equipment Model

UX-CDL11V

UX-CDL23V

UX-CDL35V

UX-CDL40V

UX-CDL45V

UX-CDL50V

Heating capacity (kW)

11

23

35

40

45

50

Heating capacity (kcal/h)

9460

19780

30100

34400

38700

43000

Gas Supply Requirements

Air inlet interface: 1/2 "thread;

Natural gas pressure range at the gas inlet of natural gas equipment: 1500Pa ~ 3500Pa, gas pressure at the equipment nozzle: 875Pa;

The pressure range of liquefied gas at the air inlet of liquefied gas equipment is 3000Pa ~ 5000Pa, and the gas pressure at the equipment nozzle is 2625Pa.

Natural gas consumption (m³)

Gas calorific value: 9000kcal/m³

1.05

2.19

3.33

3.81

4.29

4.76

Gas consumption of liquefied petroleum gas (m³)

Calorific value of gas: 25000kcal/m³

0.38

0.79

1.20

1.38

1.55

1.72

Power Supply Requirements

220V,50Hz;

Single negative pressure equipment, power distribution of each set of equipment: 125W (including burner: 5W, terminal type II fan: 120W);

Power distribution of 2 sets of equipment composite system: (burner: 5W, type III fan: 370W);

Power distribution of 3/4 sets of equipment composite system: (burner: 5W, type IV fan: 750W).

Total length (m)

3

6 (standard)/9

9 (standard)/12

12 (standard)/15

12/15 (standard)

15 (standard)/18

Total width (mm)

406

406

406

406

406

406

Total height (mm)

381

381

381

381

381

381

Fresh Air Duct and Exhaust Duct

Interface size (mm)

102

Recommended minimum installation height (m)

3.0

3.3

4.2

4.7

4.9

5.1

Weight (kg)

28

44/59

59/75

75/90

75/90

90/106

With spoiler

×

×

×

Distance from combustibles (mm)

Upper end of reflector

50

50

100

100

100

100

Both ends of the reflector

460

660

840

915

970

1020

Lower end of radiant tube

1140

1575

1800

1880

1930

1980

For example, UX-CDL50V product code explanation:

UX Canadian Factory Product Series Number

CD-Xindier brand radiant heating products.

L-linear combination form

50 -- Heating capacity 50kW

V -- negative pressure products

Related Products

Product Message

Please fill in the form information, we will answer for you as soon as possible!