  • undefined

VS-CDC series products

1. Frequency conversion products, the output power of the burner can be adjusted by the vacuum pump 2. Series-parallel system, the tail pipe required by the system is short and the heat radiation is uniform 3, flexible design, can be arbitrarily combined according to user requirements

Key words:

VS-CDC series product features

1. Frequency conversion products, the output power of the burner can be adjusted by the vacuum pump

2. Series-parallel system, the tail pipe required by the system is short and the heat radiation is uniform

3, flexible design, can be arbitrarily combined according to user requirements

4. Reflective cover design science, efficiency up to 99%

5. The control system is safe and reliable, and can control up to 6 areas

6. The vacuum pump is corrosion resistant and has various specifications

Continuous series (Premier vacuum Systems)(this equipment is suitable for exhaust gas discharge)

 

 

Technical Parameters of VS-CDC Series Products

Equipment Model

VS-CDC20

VS-CDC25

VS-CDC30

VS-CDC35

VS-CDC40

VS-CDC45

VS-CDC50

VS-CDC55

Heating capacity (kW)

20

25

30

35

40

45

50

55

Heating capacity (kcal/h)

17200

21500

25800

30100

34400

38700

43000

47300

Gas Supply Requirements

Air inlet interface: 1/2 "thread;

Natural gas pressure range at the gas inlet of natural gas equipment: 1200Pa ~ 3600Pa, gas pressure at the equipment nozzle: 0Pa;

The pressure range of liquefied gas at the air inlet of liquefied gas equipment is 2640Pa ~ 3600Pa, and the gas pressure at the equipment nozzle is 0Pa.

Gas consumption of natural gas (m3)

Gas calorific value: 9000kcal/m3

1.90

2.38

2.86

3.33

3.81

4.29

4.76

5.24

LPG gas consumption (m3)

Calorific value of gas: 25000kcal/m3

0.69

0.86

1.03

1.20

1.38

1.55

1.72

1.89

Power Supply Requirements

Burner: 220V,50Hz,10W, with grounding three-hole plug;

Type A fan: 220V,50Hz,1PH,0.75kW, pipeline connection: inlet diameter 100/152mm, outlet diameter 100mm.

Type B fan: 380V,50Hz,3PH,1.5kW, pipeline connection: inlet diameter 100mm, outlet diameter 100mm.

Total length (m)

9

9

12

12

15

15

18

18

Total width (mm)

406

406

406

406

406

406

406

406

Total height (mm)

393

393

393

393

393

393

393

393

Fresh Air Duct and Exhaust Duct

Interface size (mm)

102

Recommended minimum installation height (m)

2.4

3.3

3.8

4.3

4.8

5.0

5.2

5.4

Weight (kg)

64

64

81

81

99

99

116

116

Distance from combustibles (mm)

Upper end of reflector

50

50

100

100

100

100

100

100

Both ends of the reflector

660

720

780

840

915

970

1020

1070

Lower end of radiant tube

1575

1660

1730

1800

1880

1930

1980

2030

For example, VS-CDC50 product code explanation:

VS Canada Factory Product Series Number

CD-Xindier brand radiant heating products.

C- continuous series products

50 -- Heating capacity 50kW

Related Products