UX-CDU series products
UX-CDU product features 1. Concentrated intensification for local heating applications 2. Easy to install-both end plate brackets allow ground assembly and lifting in place 3. For negative pressure equipment, due to the proximity of the fan and the burner, the wiring cost is reduced
Key words:
Classification:
UX-CDU product features
1. Concentrated intensification for local heating applications
2. Easy to install-both end plate brackets allow ground assembly and lifting in place
3. For negative pressure equipment, due to the proximity of the fan and the burner, the wiring cost is reduced
(I) micro positive pressure (The micro positive pressure), U type, monomer (Single) series (this kind of equipment is suitable for exhaust gas)

Technical Parameters of UX-CDU Series Products
|
Equipment Model |
UX-CDU23 |
UX-CDU35 |
UX-CDU40 |
UX-CDU45 |
UX-CDU50 |
|
Heating capacity (kW) |
23 |
35 |
40 |
45 |
50 |
|
Heating capacity (kcal/h) |
19780 |
30100 |
34400 |
38700 |
43000 |
|
Gas Supply Requirements |
Air inlet interface: 1/2 "thread; Natural gas pressure range at the gas inlet of natural gas equipment: 1500Pa ~ 3500Pa, gas pressure at the equipment nozzle: 875Pa; The pressure range of liquefied gas at the air inlet of liquefied gas equipment is 3000Pa ~ 5000Pa, and the gas pressure at the equipment nozzle is 2625Pa. |
||||
|
Gas consumption of natural gas (m3) Gas calorific value: 9000kcal/m3 |
2.19 |
3.33 |
3.81 |
4.29 |
4.76 |
|
LPG gas consumption (m3) Calorific value of gas: 25000kcal/m3 |
0.79 |
1.20 |
1.38 |
1.55 |
1.72 |
|
Power Supply Requirements |
220V,50Hz; Single-unit equipment, power distribution of each set of equipment: 65W (including burner: 5W, small fan: 60W); |
||||
|
Total length (m) |
3.5 |
6.5 |
6.5 |
9.5 |
9.5 |
|
Total width (mm) |
916 |
916 |
916 |
916 |
916 |
|
Total height (mm) |
373 |
373 |
373 |
373 |
373 |
|
Fresh Air Duct and Exhaust Duct Interface size (mm) |
102 |
||||
|
Recommended minimum installation height (m) |
3.1 |
4.3 |
4.8 |
5.0 |
5.2 |
|
Weight (kg) |
52 |
83 |
83 |
114 |
114 |
|
With spoiler |
√ |
√ |
× |
× |
× |
|
Distance from combustibles (mm) |
|||||
|
Upper end of reflector |
50 |
100 |
100 |
100 |
100 |
|
Both ends of the reflector |
680 |
860 |
935 |
990 |
1040 |
|
Lower end of radiant tube |
1595 |
1820 |
1900 |
1950 |
2000 |
For example, UX-CDU50 product code explanation:
UX Canadian Factory Product Series Number
CD-Xindier brand radiant heating products.
U--U combination form
50 -- Heating capacity 50kW
(II) Micro-negative pressure (Negative pressure), U-shaped, Single/compound (Complex) series (such equipment is suitable for exhaust gas discharge)

Technical Parameters of UX-CDU()V Series Products
|
Equipment Model |
UX-CDU23V |
UX-CDU35V |
UX-CDU40V |
UX-CDU45V |
UX-CDU50V |
|
Heating capacity (kW) |
23 |
35 |
40 |
45 |
50 |
|
Heating capacity (kcal/h) |
19780 |
30100 |
34400 |
38700 |
43000 |
|
Gas Supply Requirements |
Air inlet interface: 1/2 "thread; Natural gas pressure range at the gas inlet of natural gas equipment: 1500Pa ~ 3500Pa, gas pressure at the equipment nozzle: 875Pa; The pressure range of liquefied gas at the air inlet of liquefied gas equipment is 3000Pa ~ 5000Pa, and the gas pressure at the equipment nozzle is 2625Pa. |
||||
|
Gas consumption of natural gas (m3) Gas calorific value: 9000kcal/m3 |
2.19 |
3.33 |
3.81 |
4.29 |
4.76 |
|
LPG gas consumption (m3) Calorific value of gas: 25000kcal/m3 |
0.79 |
1.20 |
1.38 |
1.55 |
1.72 |
|
Power Supply Requirements |
220V,50Hz; Single negative pressure equipment, power distribution of each set of equipment: 125W (including burner: 5W, terminal type II fan: 120W); Power distribution of 2 sets of equipment composite system: (burner: 5W, type III fan: 370W); Power distribution of 3/4 sets of equipment composite system: (burner: 5W, type IV fan: 750W). |
||||
|
Total length (m) |
3.5 |
6.5 |
6.5 |
9.5 |
9.5 |
|
Total width (mm) |
916 |
916 |
916 |
916 |
916 |
|
Total height (mm) |
373 |
373 |
373 |
373 |
373 |
|
Fresh Air Duct and Exhaust Duct Interface size (mm) |
102 |
||||
|
Recommended minimum installation height (m) |
3.1 |
4.3 |
4.8 |
5.0 |
5.2 |
|
Weight (kg) |
52 |
83 |
83 |
114 |
114 |
|
With spoiler |
√ |
√ |
× |
× |
× |
|
Distance from combustibles (mm) |
|||||
|
Upper end of reflector |
50 |
100 |
100 |
100 |
100 |
|
Both ends of the reflector |
680 |
860 |
935 |
990 |
1040 |
|
Lower end of radiant tube |
1595 |
1820 |
1900 |
1950 |
2000 |
For example, UX-CDU50V product code explanation:
UX Canadian Factory Product Series Number
CD-Xindier brand radiant heating products.
U--U combination form
50 -- Heating capacity 50kW
V -- negative pressure products
Related Products