TX-CDD series products
1. Two-stage fire products, dual output power and self-diagnosis ignition module, more economical and energy-saving operation 2. More uniform heat distribution and higher combustion efficiency 3, higher quality production materials
Key words:
Classification:
TX-CDD series product features
1. Two-stage fire products, dual output power and self-diagnosis ignition module, more economical and energy-saving operation
2. More uniform heat distribution and higher combustion efficiency
3, higher quality production materials
4. Easy to install and maintain
Two fire series (this equipment is suitable for internal exhaust)

Technical Parameters of TX-CDD Series Products
|
Equipment Model |
TX-CDD11/8.5 |
TX-CDD23/17.5 |
TX-CDD35/27.5 |
TX-CDD40/32 |
TX-CDD45/35 |
TX-CDD50/38 |
|
Heating capacity (kW) |
11/8.5 |
23/17.5 |
35/27.5 |
40/32 |
45/35 |
50/38 |
|
Heating capacity (kcal/h) |
9460/7310 |
19780/15050 |
30100/23650 |
34400/27520 |
38700/30100 |
43000/32680 |
|
Gas Supply Requirements |
Air inlet interface: 1/2 "thread; Natural gas pressure range at the gas inlet of natural gas equipment: 1500Pa ~ 3500Pa, Gas pressure at equipment nozzle (high fire):875Pa, gas pressure at equipment nozzle (low fire):600Pa; Pressure range of liquefied gas at the inlet of liquefied gas equipment: 2875Pa ~ 3500Pa, Gas pressure at equipment nozzle (high fire):2625Pa, gas pressure at equipment nozzle (low fire):1550Pa. |
|||||
|
Gas consumption of natural gas (m3) Gas calorific value: 8900kcal/m3 |
1.05/0.81 |
2.19/1.67 |
3.33/2.62 |
3.81/3.05 |
4.29/3.33 |
4.76/3.62 |
|
LPG gas consumption (m3) Calorific value of gas: 25000kcal/m3 |
0.38/0.29 |
0.79/0.60 |
1.20/0.95 |
1.38/1.10 |
1.55/1.20 |
1.72/1.31 |
|
Power Supply Requirements |
220V,50Hz; Single micro-positive pressure equipment burner power distribution: 65W (including type I fan in the burner: 60W) |
|||||
|
Total length (m) |
3 |
6 (standard)/9 |
9 (standard)/12 |
12 (standard)/15 |
12/15 (standard) |
15 (standard)/18 |
|
Total width (mm) |
406 |
406 |
406 |
406 |
406 |
406 |
|
Total height (mm) |
373 |
373 |
373 |
373 |
373 |
373 |
|
Fresh Air Duct and Exhaust Duct Interface size (mm) |
102 |
|||||
|
Recommended minimum installation height (m) |
3.0 |
3.3 |
4.2 |
4.7 |
4.9 |
5.1 |
|
Weight (kg) |
28 |
44/59 |
59/75 |
75/90 |
75/90 |
90/106 |
|
With spoiler |
× |
√ |
√ |
√ |
√ |
√ |
|
Distance from combustibles (mm) |
||||||
|
Upper end of reflector |
50 |
50 |
100 |
100 |
100 |
100 |
|
Both ends of the reflector |
460 |
660 |
840 |
915 |
970 |
1020 |
|
Lower end of radiant tube |
1140 |
1575 |
1800 |
1880 |
1930 |
1980 |
For example, TX-CDD50/38 product code explanation:
TX-Canadian Factory Product Series Number
CD-Xindier brand radiant heating products.
D -- two fire series products
50/38 -- high fire heating capacity 50kW, low fire heating capacity 38kW
Related Products
Product Message