Technical Parameters of TX-CDD Series Products

Equipment Model

TX-CDD11/8.5

TX-CDD23/17.5

TX-CDD35/27.5

TX-CDD40/32

TX-CDD45/35

TX-CDD50/38

Heating capacity (kW)

11/8.5

23/17.5

35/27.5

40/32

45/35

50/38

Heating capacity (kcal/h)

9460/7310

19780/15050

30100/23650

34400/27520

38700/30100

43000/32680

Gas Supply Requirements

Air inlet interface: 1/2 "thread;

Natural gas pressure range at the gas inlet of natural gas equipment: 1500Pa ~ 3500Pa,

Gas pressure at equipment nozzle (high fire):875Pa, gas pressure at equipment nozzle (low fire):600Pa;

Pressure range of liquefied gas at the inlet of liquefied gas equipment: 2875Pa ~ 3500Pa,

Gas pressure at equipment nozzle (high fire):2625Pa, gas pressure at equipment nozzle (low fire):1550Pa.

Gas consumption of natural gas (m3)

Gas calorific value: 8900kcal/m3

1.05/0.81

2.19/1.67

3.33/2.62

3.81/3.05

4.29/3.33

4.76/3.62

LPG gas consumption (m3)

Calorific value of gas: 25000kcal/m3

0.38/0.29

0.79/0.60

1.20/0.95

1.38/1.10

1.55/1.20

1.72/1.31

Power Supply Requirements

220V,50Hz;

Single micro-positive pressure equipment burner power distribution: 65W (including type I fan in the burner: 60W)

Total length (m)

3

6 (standard)/9

9 (standard)/12

12 (standard)/15

12/15 (standard)

15 (standard)/18

Total width (mm)

406

406

406

406

406

406

Total height (mm)

373

373

373

373

373

373

Fresh Air Duct and Exhaust Duct

Interface size (mm)

102

Recommended minimum installation height (m)

3.0

3.3

4.2

4.7

4.9

5.1

Weight (kg)

28

44/59

59/75

75/90

75/90

90/106

With spoiler

×

Distance from combustibles (mm)

Upper end of reflector

50

50

100

100

100

100

Both ends of the reflector

460

660

840

915

970

1020

Lower end of radiant tube

1140

1575

1800

1880

1930

1980

 

For example, TX-CDD50/38 product code explanation:

TX-Canadian Factory Product Series Number

CD-Xindier brand radiant heating products.

D -- two fire series products

50/38 -- high fire heating capacity 50kW, low fire heating capacity 38kW

Related Products

Product Message

Please fill in the form information, we will answer for you as soon as possible!
+86
  • +86 CN
Submit